What was found
DURING 2S CHECK FOUND LEVEL 2 CORROSION ON FLOORBEAM BETWEEN FR65 TO 66, Y1500. REPLACED FLOORBEAM IAW SRM 51-72-11 & DRAWING D53474250.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK FOUND LEVEL 2 CORROSION ON FLOORBEAM BETWEEN FR65 TO 66, Y1500. REPLACED FLOORBEAM IAW SRM 51-72-11 & DRAWING D53474250.