Service difficulty report · Duct Clamp · Emb ERJ190100IGW

Difficulty date
October 25, 2011
Submitted
October 27, 2011
Operation
Air carrier
Aircraft
N944UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000058
Aircraft time
10,089 hours, 8,604 cycles
Part
Duct Clamp
Condition
Loose
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 1824, IAH - PHL - NR 1 BLEED LEAK MESSAGE ON EICAS AS WE CLIMBED THRU FL 200. THE AIRCRAFT ALSO HAD THE NR 2 PACK AND APU ON MEL. THIS REQUIRED A NORMAL DESCENT TO 10,000FT. THE CABIN OXYGEN MASK WERE NOT DEPLOYED. FLIGHT DIVERTED TO DFW AND LANDED WITHOUT INCIDENT. EMS ALSO MET THE AIRCRAFT UPON ARRIVAL DUE TO PASSENGER COMPLANITS OF BEING UNCOMFORTABLY WARM. MAINTENANCE FOUND DUCT CLAMP LOOSE IN NR 1 PYLON, TIGHTENED CLAMP. LEAK CHECK GOOD RUN ENGS & PACKS FOR 10 MINS NO FAULTS NOTED. OK FOR SERVICE.