DURING CRUISE, EN ROUTE FROM BDL TO CLT, CREW REPORTED THE NOSE LANDING GEAR RED INDICATOR LIGHT ILLUMINATED. ON GEAR EXTENSION, ALL GEAR INDICATIONS WERE NORMAL. ON LANDING AND ROLL OUT, GEAR INDICATIONS WERE ALSO NORMAL. AN EMERGENCY WAS DECLARED AS A PRECAUTION. MAINTENANCE REPLACED THE NOSE LANDING GEAR DOWNLOCK SENSOR S845 IAW 32-61-51 FOR INTERMITTENT NEAR STATE FAULT. ALSO, REPLACED NOSE LANDING GEAR UPLOCK SENSOR S846 IAW 32-61-41 FOR CONDITION. PERFORMED SATISFACTORY NLG RETRACTION AND EXTENSION TEST. NORMAL OPERATION AND INDICATION.