What was found
2S CHECK - WATER INGRESS FOUND ON RIGHT ELEVATOR TOP SKIN PANEL BETWEEN STAB STATION 527 TO STAB STATION 589, BETWEEN RIB 12 TO RIB 13, 5.5 INCHES FROM LEADING EDGE. REPAIRED RIGHT ELEVATOR TOP SKIN PANEL BETWEEN STAB STATION 527 TO STAB STATION 589, BETWEEN RIB 12 TO RIB 13, 5.5 INCHES FROM LEADING EDGE IAW A320 SRM 55-21-11.