What was found
PHL - FLT 751 EN ROUTE BRU TO PHL. ON DESCENT, THE FLIGHT DECLARED AN EMERGENCY DUE TO EICAS MESSAGES "APU BLEED VAL", "L HYD ELE PUMP", "C HYD ELE 2", "ANTI-SKID", "PROBE HEAT", "RT UTIL BUS OFF", "R RECIRC FAN", AND "L ENG EEC". THE CIRCUIT BREAKER FOR THE RIGHT DC BUS SECT 1 WAS THEN FOUND POPPED. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE RESET THE DC BUS SECT 1 CIRCUIT BREAKER. OPERATIONALLY CHECKS NORMAL. NO FAULTS WERE NOTED.