What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON UPPER SURFACE OF CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY BETWEEN FR16 TO FR20, S23R. REPLACED CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON UPPER SURFACE OF CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY BETWEEN FR16 TO FR20, S23R. REPLACED CENTER FITTING AT RIGHT FORWARD SERVICE DOORWAY IAW A319 SRM 51-72-11.