What was found
C11 CHECK, LEVEL 2 GALVANIC CORROSION ON SILL BETWEEN FR66+5 INCHES TO FR67+16 INCHES, S23R. REPLACED SILL IAW SRM 51-72-11, DRAWING D53480048.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK, LEVEL 2 GALVANIC CORROSION ON SILL BETWEEN FR66+5 INCHES TO FR67+16 INCHES, S23R. REPLACED SILL IAW SRM 51-72-11, DRAWING D53480048.