C11 CHECK, LEVEL 2 GALVANIC CORROSION ON SHAPE SILL BETWEEN FR66+5 INCHES TO FR67+16 INCHES, S23L. REPLACED SHAPE SILL IAW SRM 51-72-11 & DRAWING D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK, LEVEL 2 GALVANIC CORROSION ON SHAPE SILL BETWEEN FR66+5 INCHES TO FR67+16 INCHES, S23L. REPLACED SHAPE SILL IAW SRM 51-72-11 & DRAWING D53480505.