What was found
2S CHECK - EXCESS PLAY ON RUDDER HINGE POINT NR 4 AT VERTICLE STAB STA 263, RIB 6. REPLACED HINGE FITTING NR 4 AND FASTENERS AT VERTICLE STAB STA 263, RIB 6 IAW A319 SRM 51-72-11 AND AMM 55-36-41-400-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - EXCESS PLAY ON RUDDER HINGE POINT NR 4 AT VERTICLE STAB STA 263, RIB 6. REPLACED HINGE FITTING NR 4 AND FASTENERS AT VERTICLE STAB STA 263, RIB 6 IAW A319 SRM 51-72-11 AND AMM 55-36-41-400-001.