Service difficulty report · Cooling Fan · Airbus A321211

Difficulty date
May 16, 2012
Submitted
May 17, 2012
Operation
Air carrier
Aircraft
N162UW
Make and model
Airbus A321211
Aircraft serial
1412
Aircraft time
39,178 hours, 14,090 cycles
Part
Cooling Fan
Part number
36161407
Part serial
R2461
Condition
Leaking
Location
Apu
Part time
178 hours, 61 cycles
Stage of operation
TX
How discovered
O
Nature of condition
K, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED AN OILY SMELL IN CABIN AT GATE WITH APU BLEED ON. FOUND OIL LEAK ON APU COOLING FAN. REPLACED COOLING FAN. ALSO REPLACED ALL PACK COMPONENTS DUE TO CONTAMINATION, PERFORMED APU WASH AND DECONTAMINATION.