C11 CHECK - FLOORBEAM CORRODED BETWEEN BS 808 AND BS 950 AT Y -189. REMOVED AND REPLACED FLOORBEAM IAW A319 SRM 51-72-11 AND DRAWING D53111406.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK - FLOORBEAM CORRODED BETWEEN BS 808 AND BS 950 AT Y -189. REMOVED AND REPLACED FLOORBEAM IAW A319 SRM 51-72-11 AND DRAWING D53111406.