What was found
2S CHECK - FLOORBEAM AUXILIARY RAIL CORRODED AT FR 16, Y 503.2. REMOVED AND REPLACED FLOORBEAM AUXILIARY RAIL I.A.W A319 SRM 51-72-11 AND DRAWING D53112825.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - FLOORBEAM AUXILIARY RAIL CORRODED AT FR 16, Y 503.2. REMOVED AND REPLACED FLOORBEAM AUXILIARY RAIL I.A.W A319 SRM 51-72-11 AND DRAWING D53112825.