What was found
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67, Y465. REPLACED FLOORBEAM BETWEEN FR64 TO FR67, Y465 IAW A319 SRM 51-42-12 FIGS 1 & 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67, Y465. REPLACED FLOORBEAM BETWEEN FR64 TO FR67, Y465 IAW A319 SRM 51-42-12 FIGS 1 & 2.