As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
2S CHECK - CORROSION FOUND ON RIGHT WING INTERCONNECTING STRUT INTERNAL AREA OF HOUSING DURING DISASSEMBLY BETWEEN INBOARD & OUTBOARD FLAP AT RIB 9. REPLACED RIGHT WING INTERCONNECTING STRUT IAW A319 AMM 27-51-44 & JOB CARD 26C67057001.