What was found
C11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y189. REPLACED FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y189 IAW A319 SRM 51-42-11, PAR. 7, FIG 12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y189. REPLACED FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y189 IAW A319 SRM 51-42-11, PAR. 7, FIG 12.