What was found
C11/SY6 CHECK - EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66 PLUS 10 INCHES, Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66 PLUS 10 INCHES, Y1292 IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11/SY6 CHECK - EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66 PLUS 10 INCHES, Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR66 PLUS 10 INCHES, Y1292 IAW A319 SRM 51-42-11.