As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66+5 INCHES TO FR67+15 INCHES & BETWEEN -Y1292 TO -Y1162. REPLACED FLOORBEAM BETWEEN FR66+5 INCHES TO FR67+15 INCHES & BETWEEN -Y1292 TO -Y1162 IAW A319 SRM 51-42-11 & AIRBUS DRAWING D53472780.