As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DEPARTED PVD WITH MEL 49-01A ASSIGNED (APU WON'T START). EN ROUTE TO CLT, NR 2 GENERATOR DROPPED OFF LINE. AT FIRST, IT WOULD NOT RESET. COMPLETED CHECKLIST AND GENERATOR RESET. ALL INDICATIONS NORMAL. CONTINUED TO CLT AND LANDED WITHOUT INCIDENT. MX TROUBLESHOT FOR LV TRIP AND FLUCTUATING VOLTAGE REF 24-21-00 PB 101. REPLACED NR 2 GCU IAW AMM 24-21-81. SUBSEQUENT ENGINE RUN REVEALS NORMAL STABLE PARAMETERS. AC GENERATOR SYSTEM CHECKS SATISFACTORY IAW 24-21-00-735-001.