What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON THE CENTER FITTING OF THE RIGHT FORWARD DOOR THRESHOLD AREA BETWEEN FR16 TO FR20, S23R, -Y1732. REPLACED RIGHT FORWARD DOOR THRESHOLD CENTER FITTING IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON THE CENTER FITTING OF THE RIGHT FORWARD DOOR THRESHOLD AREA BETWEEN FR16 TO FR20, S23R, -Y1732. REPLACED RIGHT FORWARD DOOR THRESHOLD CENTER FITTING IAW A319 SRM 51-72-11.