What was found
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FR69 TO FR70, S23R. REPLACED FLOOR SUPPORT BETWEEN FR69 TO FR70, S23R IAW A319 SRM 51-42-11, 51-44-11 & 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FR69 TO FR70, S23R. REPLACED FLOOR SUPPORT BETWEEN FR69 TO FR70, S23R IAW A319 SRM 51-42-11, 51-44-11 & 51-75-12.