What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON CENTER FITTING AT L2 DOOR ENTRYWAY BETWEEN FR66 TO FR68, S23L, Y1732. REPLACED CENTER FITTING AT L2 DOOR ENTRYWAY BETWEEN FR66 TO FR68, S23L, Y1732 IAW A321 SRM 51-72-11 & AIRBUS DRAWING D53480505.