What was found
C2 CHECK - EMERGENCY POWER SUPPLY NR 5 FAILS TEST. BATTERY FAILED TEST, LIGHT ASSEMBLY INOP AT AFT PASSENGER DOOR. REPLACED EMERGENCY POWER SUPPLY NR 5 IAW EMBRAER E190 AMM 33-50-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C2 CHECK - EMERGENCY POWER SUPPLY NR 5 FAILS TEST. BATTERY FAILED TEST, LIGHT ASSEMBLY INOP AT AFT PASSENGER DOOR. REPLACED EMERGENCY POWER SUPPLY NR 5 IAW EMBRAER E190 AMM 33-50-01.