What was found
S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BEAM AT FR16, Y503.2. REPLACED FLOORBEAM BEAM AT FR16, Y503.2 IAW A321 IPC 53-11-01-05J & AIRBUS DRAWING D53112758.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BEAM AT FR16, Y503.2. REPLACED FLOORBEAM BEAM AT FR16, Y503.2 IAW A321 IPC 53-11-01-05J & AIRBUS DRAWING D53112758.