What was found
C4 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BS 764 TO BS 859, RBL 33. REPLACED FLOOR SUPPORT BS 764 TO BS 859, RBL 33 IAW B767 SRM 51-40-02, 51-20-01 & 51-21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BS 764 TO BS 859, RBL 33. REPLACED FLOOR SUPPORT BS 764 TO BS 859, RBL 33 IAW B767 SRM 51-40-02, 51-20-01 & 51-21-00.