What was found
MAINTENANCE REPORTED THE EMERGENCY LIGHT TEST GIVES MESSAGE: "ESPU UNIT EMER R". MAINTENANCE REPLACED RIGHT OVERWING EXIT POWER SUPPLY AND BATTERY PER AMM 33-51-38-400-001-A. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTENANCE REPORTED THE EMERGENCY LIGHT TEST GIVES MESSAGE: "ESPU UNIT EMER R". MAINTENANCE REPLACED RIGHT OVERWING EXIT POWER SUPPLY AND BATTERY PER AMM 33-51-38-400-001-A. OPS CHECK GOOD.