What was found
S3 CHECK - ELONGATED HOLE ON FRAME FITTING AT R2 DOOR CUTOUT AT STOP FITTING NR 1 AT FR66, S22R. ACCOMPLISHED INTERIM REPAIR ON FRAME FITTING AT R2 DOOR CUTOUT AT STOP FITTING NR 1 AT FR66, S22R IAW EA 503840A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S3 CHECK - ELONGATED HOLE ON FRAME FITTING AT R2 DOOR CUTOUT AT STOP FITTING NR 1 AT FR66, S22R. ACCOMPLISHED INTERIM REPAIR ON FRAME FITTING AT R2 DOOR CUTOUT AT STOP FITTING NR 1 AT FR66, S22R IAW EA 503840A.