What was found
2S CHECK - FOUND WATER INDICATOR ON RUDDER LEFT SIDE PANEL AFT OF NR 14 T/E FASTENER MEASURING 15IN AREA. CLEANED AREA, REMOVED PAINT AND SKIN AND CORE AT DAMAGED AREA 5.5 X 3.5 PERFORMED DRYING PROCESS OF THE AREA RUDDER (EA 502598 STEP 4.C). PERFORMED WATER BREAK TEST SRM 51-77-11 PG 39, BONDED CORE (CORE SIZE 5.5 X 3.5), INSTALLED ADHESIVE FILLER AT L/E SIDE OF THE RUDDER IAW EA 502598.