What was found
2S CHECK, ELONGATED HOLE ON FLOORBEAM LOWER COUPLING AT FR66, S23L. REPLACED FLOORBEAM LOWER COUPLING AT FR66, S23L IAW SRM 51-72-11 AND DWG D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK, ELONGATED HOLE ON FLOORBEAM LOWER COUPLING AT FR66, S23L. REPLACED FLOORBEAM LOWER COUPLING AT FR66, S23L IAW SRM 51-72-11 AND DWG D53472815.