What was found
2S CHECK, CORROSION ON FLOOR SUPPORT BETWEEN FR 12 TO 24, Y254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11, 51-42-11, AND DWG D53112816.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK, CORROSION ON FLOOR SUPPORT BETWEEN FR 12 TO 24, Y254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11, 51-42-11, AND DWG D53112816.