What was found
2S CHECK - ELONGATED HOLE ON FLOORBEAM COUPLING AT FR65, Y1732. REPLACED FLOORBEAM COUPLING AT FR65, Y1732 IAW SRM 51-72-11 AND DWG D53472750.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - ELONGATED HOLE ON FLOORBEAM COUPLING AT FR65, Y1732. REPLACED FLOORBEAM COUPLING AT FR65, Y1732 IAW SRM 51-72-11 AND DWG D53472750.