What was found
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR47.2 TO FR47.4, -Y1732. REPLACED FLOOR SUPPORT BEAM BETWEEN FR47.2 TO FR47.4, Y1732 IAW SRM 53-00-14, FIG 102 AND 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR47.2 TO FR47.4, -Y1732. REPLACED FLOOR SUPPORT BEAM BETWEEN FR47.2 TO FR47.4, Y1732 IAW SRM 53-00-14, FIG 102 AND 51-42-11.