What was found
SYS CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL BETWEEN FR14 TO FR16, Y503. REPLACED DUMMY RAIL BETWEEN FR14 TO FR16, Y503 IAW SRM 51-42-11 & 53-11-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SYS CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL BETWEEN FR14 TO FR16, Y503. REPLACED DUMMY RAIL BETWEEN FR14 TO FR16, Y503 IAW SRM 51-42-11 & 53-11-14.