What was found
SYS CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT AT FR16, Y254. REPLACED FLOOR SUPPORT AT FR16, Y254 IAW SRM 53-11-14, 51-72-11 & 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SYS CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT AT FR16, Y254. REPLACED FLOOR SUPPORT AT FR16, Y254 IAW SRM 53-11-14, 51-72-11 & 51-42-11.