What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FR12 TO FR16, Y503.2. REPLACED FLOOR SUPPORT BETWEEN FR12 TO FR16, Y503.2 IAW SRM 51-74-00, 53-11-14 & 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FR12 TO FR16, Y503.2. REPLACED FLOOR SUPPORT BETWEEN FR12 TO FR16, Y503.2 IAW SRM 51-74-00, 53-11-14 & 51-42-11.