What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, Y81. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, -Y81 IAW SRM 51-72-11 & DWG D53112828 & D53110984.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, Y81. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, -Y81 IAW SRM 51-72-11 & DWG D53112828 & D53110984.