What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON CENTER SHAPE SILL FITTING BETWEEN FR66+5 " TO FR67+16", S23R. REPLACED CENTER SHAPE SILL FITTING BETWEEN FR66+5" TO FR67+16", S23R IAW SRM 51-72-11 & DWG D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON CENTER SHAPE SILL FITTING BETWEEN FR66+5 " TO FR67+16", S23R. REPLACED CENTER SHAPE SILL FITTING BETWEEN FR66+5" TO FR67+16", S23R IAW SRM 51-72-11 & DWG D53480505.