What was found
Q4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM UPPER T-CAP AT BS312 & BETWEEN LBL 10 TO LBL 12. REPAIRED FLOORBEAM UPPER T-CAP AT BS312 & BETWEEN LBL 10 TO LBL 12 IAW SRM 53-10-51-2R & 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
Q4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM UPPER T-CAP AT BS312 & BETWEEN LBL 10 TO LBL 12. REPAIRED FLOORBEAM UPPER T-CAP AT BS312 & BETWEEN LBL 10 TO LBL 12 IAW SRM 53-10-51-2R & 51-40-02.