What was found
Q4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON MAIN ENTRY DOOR Z-ANGLE SPLICE PLATE BETWEEN BS358 TO BS362, WL208. REPLACED MAIN ENTRY DOOR Z-ANGLE SPLICE PLATE BETWEEN BS358 TO BS362, WL208 IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
Q4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON MAIN ENTRY DOOR Z-ANGLE SPLICE PLATE BETWEEN BS358 TO BS362, WL208. REPLACED MAIN ENTRY DOOR Z-ANGLE SPLICE PLATE BETWEEN BS358 TO BS362, WL208 IAW SRM 51-40-02.