What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y1584. REPLACED FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y1584 IAW SRM 53-00-14, 51-42-11, & 51-44-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y1584. REPLACED FLOOR SUPPORT BEAM BETWEEN FR20 TO FR24, -Y1584 IAW SRM 53-00-14, 51-42-11, & 51-44-11.