What was found
2S CHECK - CORROSION ON SHAPE SILL (CENTER FITTING) BETWEEN FR66 TO FR68, S23R. REPLACED SHAPE SILL (CENTER FITTING) BETWEEN FR66 TO FR68, S23R IAW SRM 51-72-11, DWG, D53480048 & D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - CORROSION ON SHAPE SILL (CENTER FITTING) BETWEEN FR66 TO FR68, S23R. REPLACED SHAPE SILL (CENTER FITTING) BETWEEN FR66 TO FR68, S23R IAW SRM 51-72-11, DWG, D53480048 & D53480505.