What was found
DURING 2S CHECK, CORROSION FOUND ON R2 DOOR SILL AT FR68, -Z500, -Y1760. REPLACED R2 DOOR SILL IAW SRM 51-72-11, DWG D53480505 & D53474250.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, CORROSION FOUND ON R2 DOOR SILL AT FR68, -Z500, -Y1760. REPLACED R2 DOOR SILL IAW SRM 51-72-11, DWG D53480505 & D53474250.