DURING 2S CHECK, CORROSION FOUND ON R1 DOOR CENTER SILL BETWEEN FR16 TO FR 18, -Y1379.5. REPLACED SILL IAW SRM 51-74-00 AND 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, CORROSION FOUND ON R1 DOOR CENTER SILL BETWEEN FR16 TO FR 18, -Y1379.5. REPLACED SILL IAW SRM 51-74-00 AND 51-42-11.