What was found
DURING 2S CHECK, FOUND CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254. REPLACED SUPPORT FLOOR IAW SRM 51-72-11, DWG D53112816, D53112639 AND D53115054.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254. REPLACED SUPPORT FLOOR IAW SRM 51-72-11, DWG D53112816, D53112639 AND D53115054.