What was found
DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT AT FR66, Y765. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, 51-44-11 AND 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT AT FR66, Y765. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, 51-44-11 AND 51-42-11.