What was found
DURING 2S CHECK - FOUND CORROSION ON FLOORBEAM COUPLING AT FR66 + 5", Y1162. REPLACED FLOORBEAM COUPLING IAW SRM 51-72-11 & DWG NR D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK - FOUND CORROSION ON FLOORBEAM COUPLING AT FR66 + 5", Y1162. REPLACED FLOORBEAM COUPLING IAW SRM 51-72-11 & DWG NR D53472815.