What was found
2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FR66+5" TO FR67+15", Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - CORROSION ON FLOOR SUPPORT BETWEEN FR66+5" TO FR67+15", Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.