What was found
DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT BETWEEN FR 68-69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, 51-44-11 & 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT BETWEEN FR 68-69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, 51-44-11 & 51-42-11.