DURING 2S CHECK, FOUND CORROSION ON FLOORBEAM BETWEEN FR 65 - 66, -Y465. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, FIG. 102 & 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND CORROSION ON FLOORBEAM BETWEEN FR 65 - 66, -Y465. REPLACED FLOOR SUPPORT IAW SRM 53-00-14, FIG. 102 & 51-42-11.