What was found
DURING Q3 CHECK, A CRACK WAS FOUND ON STRINGER SPLICE AT BS 907, S4R. REPLACED STRINGER SPLICE IAW SRM 51-40-02 & DWG 65-45772.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING Q3 CHECK, A CRACK WAS FOUND ON STRINGER SPLICE AT BS 907, S4R. REPLACED STRINGER SPLICE IAW SRM 51-40-02 & DWG 65-45772.