DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT BETWEEN FR67+15" TO 69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 2S CHECK, FOUND CORROSION ON FLOOR SUPPORT BETWEEN FR67+15" TO 69, -Y1162. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DWG D53472780.